Manufacturer Analytical
Features
Measurement range | 0-100% oxygen |
Accuracy | < ±2% of FS range under constant conditions |
Response time | T90 < 10 seconds |
Sensitivity (LDL) | 0.50% |
Linearity | ±1% under constant conditions |
Sensor model | AII-11-75-PO2 |
Sensor life at 25°C (77°F) and 1 atmosphere | 32 months in air 5°C (77°F) and 1 atmosphere |
Calibration interval | Prior to use and after 8 hours operation |
Inlet pressure | Ambient or 0.34-2 barg (5-30 psig) for flow through connector |
Flow rate (constant) | 0.2-10 Nl/min (0.4-20 SCFH) |
Gas connections | 1x16 mm thread |
Display | 3 digit LCD 2.8 x 1.6cm (1.1 x 0.625"); resolution 0.1 |
Dimensions | 6.9 x 10.4 x 3.4cm (2.72" x 4.1" x 1.35") |
Weight | 196g (7oz) |
Compensation | Temperature compensated |
Alarms | User adjustable HI and LO alarms (AII-3000 M and MHC only) |
Storage temperature | -20°C to +60°C (-4°F to 140°F) on intermittent basis |
Operating temperature | 6 to 45°C (41°F to 113°F) |
Power | 2 AA alkaline batteries |
Battery Life | Up to 1300 hrs |
Humidity | Non-condensing 0-95% RH |
Warm up time | None |